  "metadata": {
    "id": "rev-11-1863-pk4-40a-ato-breaker",
    "name": "40A ATO Auto-resetting Breaker - 4 Pack",
    "type": "circuit_breaker",
    "manufacturer": "REV Robotics",
    "part_number": "REV-11-1863-PK4",
    "datasheet_url": "https://www.revrobotics.com/content/docs/REV-11-1860-1863-DS.pdf",
    "description": "12VDC, 40A custom ATO-format auto-resetting (Type I) thermal circuit breaker in an orange anodized aluminum case; meets SAE J553. Designed to protect FRC robot actuator branch circuits. Two ATO/ATC blade terminals (power in / power out) make it a pass-through inline protection device. Auto-resetting Type I: a thermal element trips on sustained over-current and re-closes automatically after the element cools. Holds 100% of the 40A rating for >=1800 s; trips in 5-60 s at 200% rated current. Color-coded (orange = 40A) anodized aluminum case with stamped 12V / 40A ratings for easy identification. Sold as a 4-pack (REV-11-1863-PK4); each breaker is REV-11-1863.",
    "tags": [
      "40a",
      "ato",
      "atc",
      "breaker",
      "circuit-breaker",
      "12v",
      "auto-reset",
      "type-i",
      "sae-j553",
      "thermal",
      "rev",
      "FRC",
      "4-pack"
    ],
    "taxonomy": [
      "power",
      "robotics.frc"
    ],
    "schema_version": "1.5.0",
    "version": "1.0",
    "thumbnail": "https://storage.googleapis.com/protoboard-delta.firebasestorage.app/protoparts/rev-11-1863-pk4-40a-ato-breaker/thumbnail.png"
  },
  "domains": [
    {
      "domain": "electrical",
      "supply_voltage_V": [
        12,
        12
      ],
      "pin_count": 2,
      "metadata": {
        "package_type": "ATO/ATC blade",
        "safety_standards": [
          "SAE J553"
        ]
      },
      "power_domains": [
        {
          "id": "breaker-circuit",
          "name": "Protected 12V Circuit",
          "nominal_voltage_V": 12,
          "voltage_range_V": [
            12,
            12
          ],
          "max_current_mA": 40000,
          "isolation_type": "non_isolated",
          "ground_reference": "floating",
          "description": "Series pass-through 12 VDC circuit protected by the breaker. Rated 40 A continuous (holds 100% of rated current for >=1800 s). Thermal element trips on sustained over-current (135% rated trips in 30-1800 s; 200% rated trips in 5-60 s) and auto-resets (Type I) when cooled. Voltage rating 12 VDC per datasheet. (datasheet p.1)"
        }
      ],
      "resources": [
        {
          "id": "line_blade",
          "name": "Line Blade",
          "domain": "electrical",
          "description": "ATO/ATC blade terminal, line/input side. 5.3 mm (0.21 in) wide blade, 10.0 mm (0.39 in) exposed depth, 9.4 mm (0.37 in) center-to-center spacing from the load blade. The breaker is a non-polarized in-line series device; 'in' vs 'out' is by convention. (datasheet p.1)",
          "functions": [
            {
              "name": "Power",
              "description": "Series current input into the breaker from the source side (e.g. PDP/PDH breaker channel or battery branch). Carries up to 40 A continuous; the protected current passes through the internal thermal element to the load blade.",
              "direction": "sink",
              "signal_class": "power",
              "shareable_with": []
            }
          ],
          "power_domain_id": "breaker-circuit",
          "connector_type": "custom",
          "has_internal_pullup": false,
          "has_internal_pulldown": false,
          "current_rating": {
            "sink": {
              "max_continuous_mA": 40000
            }
          },
          "notes": "ATO/ATC blade terminal. 40 A rated continuous; auto-resetting thermal trip above rating. (datasheet p.1)"
        },
        {
          "id": "load_blade",
          "name": "Load Blade",
          "domain": "electrical",
          "description": "ATO/ATC blade terminal, load/output side. 5.3 mm (0.21 in) wide blade, 10.0 mm (0.39 in) exposed depth, 9.4 mm (0.37 in) center-to-center spacing from the line blade. The breaker is a non-polarized in-line series device; 'in' vs 'out' is by convention. (datasheet p.1)",
          "functions": [
            {
              "name": "Load",
              "description": "Series current output from the breaker to the protected load (e.g. a motor/actuator branch). Carries up to 40 A continuous; current is interrupted when the internal thermal element trips and restored automatically on auto-reset.",
              "direction": "source",
              "signal_class": "power",
              "shareable_with": []
            }
          ],
          "power_domain_id": "breaker-circuit",
          "connector_type": "custom",
          "has_internal_pullup": false,
          "has_internal_pulldown": false,
          "current_rating": {
            "source": {
              "max_continuous_mA": 40000
            }
          },
          "notes": "ATO/ATC blade terminal. 40 A rated continuous; auto-resetting thermal trip above rating. (datasheet p.1)"
        }
      ],
      "interfaces": [
        {
          "id": "breaker_(12v/40a)",
          "name": "Breaker (12V/40A)",
          "domain": "electrical",
          "protocol": {
            "type": "power",
            "role": "peer"
          },
          "requires": [
            {
              "function": "Power",
              "count": 1
            },
            {
              "function": "Load",
              "count": 1
            }
          ],
          "constraints": {
            "max_connections": 2
          },
          "power_delivery": {
            "max_voltage_V": 12,
            "max_current_mA": 40000
          },
          "description": "Inline auto-resetting breaker connection. Carries up to 40 A at 12 VDC in series through the internal thermal element: Power is the source-side (line) ATO blade and Load is the output-side ATO blade to the protected branch. Current is interrupted on over-current trip and auto-restored (Type I) on cool-down. Non-polarized — Power/Load assignment is by convention. (datasheet p.1)"
        }
      ]
    }
  ],
  "artifacts": [
    {
      "id": "art_thumbnail",
      "name": "Thumbnail",
      "type": "image",
      "url": "https://storage.googleapis.com/protoboard-delta.firebasestorage.app/protoparts/rev-11-1863-pk4-40a-ato-breaker/thumbnail.png"
    },
    {
      "id": "art_datasheet",
      "name": "ATO Auto-Resetting Breaker Datasheet",
      "type": "datasheet",
      "url": "https://storage.googleapis.com/protoboard-delta.firebasestorage.app/protoparts/rev-11-1863-pk4-40a-ato-breaker/artifacts/art_datasheet.pdf",
      "storagePath": "protoparts/rev-11-1863-pk4-40a-ato-breaker/artifacts/art_datasheet.pdf",
      "mimeType": "application/pdf",
      "size": 154290
    },
    {
      "id": "art_cad_step",
      "name": "REV-11-1863 STEP Model",
      "type": "cad",
      "url": "https://storage.googleapis.com/protoboard-delta.firebasestorage.app/protoparts/rev-11-1863-pk4-40a-ato-breaker/artifacts/art_cad_step.STEP",
      "storagePath": "protoparts/rev-11-1863-pk4-40a-ato-breaker/artifacts/art_cad_step.STEP",
      "mimeType": "model/step",
      "size": 2093485
    },
    {
      "id": "art_product_image",
      "name": "40A Breaker Product Image",
      "type": "image",
      "url": "https://storage.googleapis.com/protoboard-delta.firebasestorage.app/protoparts/rev-11-1863-pk4-40a-ato-breaker/artifacts/art_product_image.png",
      "storagePath": "protoparts/rev-11-1863-pk4-40a-ato-breaker/artifacts/art_product_image.png",
      "mimeType": "image/png",
      "size": 131469
    },
    {
      "id": "art_product_page",
      "name": "REV Robotics Product Page",
      "type": "link",
      "url": "https://www.revrobotics.com/auto-resetting-breakers/"
    }
  ],
  "previewArtifactId": "art_thumbnail"
}